60HZ Tíðni viðskipta vatnsdæla

Til að halda stöðvunarþrýstingnum stöðugum og stöðva venjulega verður VFD vatnsdælan að búa að lágmarki 2L, hámarks 24KL þrýstitank, almennt er hann settur upp á fimm vegu, því styttri vegalengdin er, því betri eru áhrifin; því stærri sem þrýstitankur er, því betri eru áhrifin.
Hringdu í okkur

Vörukynning

Umsókn

Íbúðarhúsnæði, iðnaðar-, atvinnuhúsnæði, fjölskylduhús og einbýlishús o.fl.


Vörulýsing

image001


Tæknilegar breytur

image003


Tæknilegar upplýsingar

FyrirmyndKrafturInntaksspennaEndurflæði (m3/h)Metið höfuð (m)Einfasa PUMP líkanFramleiðslutíðniÞrýstiskynjari
VFWF-17M / 2-200,37 kW1x220V2.020CMF2-2020--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17M / 2-310,55KW1x220V2.031CMF2-30
VFWF-17M / 2-420.75KW1x220V2.042CMF2-40
VFWF-17M / 2-510.75KW1x220V2.051CMF2-50
VFWF-17M / 2-631KW1x220V2.063CMF2-60






VFWF-17M / 4-240.75KW1x220V4.024CMF4-20
VFWF-17M / 4-361KW1x220V4.036CMF4-30
VFWF-17M / 4-421.1KW1x220V4.042CMF4-40






VFWF-17M / 8-181KW1x220V8.018CMF8-10
VFWF-17M / 8-281,5KW1x220V8.028CMF8-15






VFWF-17M / 8-120.75KW1x220V8.012CMF8-10B
VFWF-17M / 8-251,5KW1x220V8.025CMF8-20B






VFWF-17M / 12-181,5KW1x220V12.018CMF12-10






VFWF-17M / 12-151.1KW1x220V12.015CMF12-10B






VFWF-17M / 16-141,5KW1x220V16.014CMF16-10


FyrirmyndKrafturInntaksspennaEndurflæði (m3/h)Metið höfuð (m)Þriggja fasa PUMP líkanFramleiðslutíðniÞrýstiskynjari
VFWF-17S / 2-200,37 kW1x220V2.020CMF2-20T (△)20--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17S / 2-310,55KW1x220V2.031CMF2-30T (△)
VFWF-17S / 2-420.75KW1x220V2.042CMF2-40T (△)
VFWF-17S / 2-510.75KW1x220V2.051CMF2-50T (△)
VFWF-17S / 2-631KW1x220V2.063CMF2-60T (△)






VFWF-17S / 4-240.75KW1x220V4.024CMF4-20T (△)
VFWF-17S / 4-361KW1x220V4.036CMF4-30T (△)
VFWF-17S / 4-421.1KW1x220V4.042CMF4-40T (△)






VFWF-17S / 8-181KW1x220V8.018CMF8-10T (△)
VFWF-17S / 8-281,5KW1x220V8.028CMF8-15T (△)
VFWF-17S / 8-361,85KW1x220V8.036CMF8-20T (△)
VFWF-17S / 8-462.2KW1x220V8.046CMF8-25T (△)






VFWF-17S / 8-120.75KW1x220V8.012CMF8-10BT (△)
VFWF-17S / 8-251,5KW1x220V8.025CMF8-20BT (△)
VFWF-17S / 8-392.2KW1x220V8.039CMF8-30BT (△)






VFWF-17S / 12-181,5KW1x220V12.018CMF12-10T (△)
VFWF-17S / 12-342.2KW1x220V12.034CMF12-15T (△)






VFWF-17S / 12-151.1KW1x220V12.015CMF12-10BT (△)
VFWF-17S / 12-312.2KW1x220V12.031CMF12-20BT (△)






VFWF-17S / 16-141,5KW1x220V16.014CMF16-10T (△)






VFWF-17S / 20-161,85KW1x220V20.016CMF20-10T (△)


FyrirmyndKrafturInntaksspennaEndurflæði (m3/h)Metið höfuð (m)Þriggja fasa PUMP líkanFramleiðslutíðniÞrýstiskynjari
VFWF-17T / 2-200,37 kW3x380V2.020CMF2-20T (Y)20--60Hz4--20mA, +24V, (10bar, 16bar, 25bar)
VFWF-17T / 2-310,55KW3x380V2.031CMF2-30T (Y)
VFWF-17T / 2-420.75KW3x380V2.042CMF2-40T (Y)
VFWF-17T / 2-510.75KW3x380V2.051CMF2-50T (Y)
VFWF-17T / 2-631KW3x380V2.063CMF2-60T (Y)






VFWF-17T / 4-240.75KW3x380V4.024CMF4-20T (Y)
VFWF-17T / 4-361KW3x380V4.036CMF4-30T (Y)
VFWF-17T / 4-421.1KW3x380V4.042CMF4-40T (Y)






VFWF-17T / 8-181KW3x380V8.018CMF8-10T (Y)
VFWF-17T / 8-281,5KW3x380V8.028CMF8-15T (Y)
VFWF-17T / 8-361,85KW3x380V8.036CMF8-20T (Y)
VFWF-17T / 8-462.2KW3x380V8.046CMF8-25T (Y)
VFWF-17T / 8-583KW3x380V8.058CMF8-30T (Y)






VFWF-17T / 8-120.75KW3x380V8.012CMF8-10BT (Y)
VFWF-17T / 8-251,5KW3x380V8.025CMF8-20BT (Y)
VFWF-17T / 8-392.2KW3x380V8.039CMF8-30BT (Y)
VFWF-17T / 8-523KW3x380V8.052CMF8-40BT (Y)
VFWF-17T / 8-653KW3x380V8.065CMF8-50BT (Y)






VFWF-17T / 12-181,5KW3x380V12.018CMF12-10T (Y)
VFWF-17T / 12-342.2KW3x380V12.034CMF12-15T (Y)
VFWF-17T / 12-363KW3x380V12.036CMF12-20T (Y)






VFWF-17T / 12-151.1KW3x380V12.015CMF12-10BT (Y)
VFWF-17T / 12-312.2KW3x380V12.031CMF12-20BT (Y)
VFWF-17T / 12-483KW3x380V12.048CMF12-30BT (Y)






VFWF-17T / 16-141,5KW3x380V16.014CMF16-10T (Y)
VFWF-17T / 16-283KW3x380V16.028CMF16-20T (Y)
VFWF-17T / 16-424KW3x380V16.042CMF16-30T (Y)






VFWF-17T / 20-161,85KW3x380V20.016CMF20-10T (Y)
VFWF-17T / 20-324KW3x380V20.032CMF20-20T (Y)


Um okkur

a) Af hverju eigum við að setja upp þrýstitank fyrir tíðnidrif vatnsdæluna?

Til að halda stöðvunarþrýstingnum stöðugum og stöðva venjulega verður VFD vatnsdælan að búa að lágmarki 2L, hámarks 24KL þrýstitank, almennt er hann settur upp á fimm vegu, því styttri vegalengdin er, því betri eru áhrifin; því stærri sem þrýstitankur er, því betri eru áhrifin.

b) Framleiðir þú eins fasa vatnsdælur með breytilegri tíðni?

Já, við framleiðum eins fasa dælur með breytilegri tíðni. Hvaða tæknilegu breytur þarftu fyrir dælur með breytilegri tíðni?

c) Hvert er verndarstig vatnsdælunnar með breytilegum hraða?

IP54.

d) Hver er næsti flugvöllur fyrirtækisins þíns?

Fyrst er Ningbo flugvöllur, þá Hangzhou eða Shanghai flugvöllur, velkomið að heimsækja okkur.

e) Ertu með tíðnibreytir með WIFI aðgerð? Hversu marga metra getur móttökufjarlægðin náð?

Já, við framleiðum tíðnibreytur sérstaklega fyrir vatnsdælur með WIFI aðgerð, hámarks móttökufjarlægð er 80 metrar.

f) Hver er munurinn á tengingu vatnsdælu milli þriggja fasa inngangs&magnara; framleiðsla og eins fasa inntak og þriggja fasa framleiðsla inverter?

Tengingaraðferðin er mismunandi: Y-tenging og △ tenging í sömu röð.


maq per Qat: 60Hz tíðni umbreyting vatnsdæla, Kína, birgja, verksmiðja, sérsniðin, ódýr, verðskrá, tilvitnun